Energy Storage AC Cabinet
DCES – 209kW | DCES-209kW-2C1 | DCES-209kW-3C1
Product Features
Product Parameters
DCES 209kW
DC Side Parameters
Max DC Voltage (V)
1500
DC Voltage Range (V)
1000~1500
Max DC Current (A)
220
AC Side Parameters
Rated Power (kW)
209
Max Apparent Power (kW)
237
Rated Current (A)
174
Max Current (A)
198
Rated Voltage (Vac)
690 (3W+PE)
Grid Voltage (Vac)
586.5~759
Rated Frequency (Hz)
45~55/55~65
Basic Parameters
Overload Capability
1.1 times (long-term), 1.2 times (1min) (temp≤30°C)
Power Factor
~1~1 leading or lagging
Total Harmonic Distortion
<3% (rated load)
Operating Temperature (°C)
-35~60 (>45 derated)
Max Operating Altitude (m)
4000 (>2000 derated)
Relative Humidity
0~95%, no condensation
Protection Grade
IP45
Anticorrosion Grade
C5
Dimensions (W*D*H) (mm)
400×1350×2380
Net Weight (T)
≤0.3
Communication
CAN/RS485/Ethernet
DCES 209kW-2C1
DC Side Parameters
Max DC Voltage (V)
1500
DC Voltage Range (V)
1000~1500
Max DC Current (A)
220*2
AC Side Parameters
Rated Power (kW)
209*2
Max Apparent Power (kW)
237*2
Rated Current (A)
174*2
Max Current (A)
198*2
Rated Voltage (Vac)
690 (3W+PE)
Grid Voltage (Vac)
586.5~759
Rated Frequency (Hz)
45~55/55~65
Basic Parameters
Overload Capability
1.1 times (long-term), 1.2 times (1min) (temp≤30°C)
Power Factor
~1~1 leading or lagging
Total Harmonic Distortion
<3% (rated load)
Operating Temperature (°C)
-35~60 (>45 derated)
Max Operating Altitude (m)
4000 (>2000 derated)
Relative Humidity
0~95%, no condensation
Protection Grade
IP45
Anticorrosion Grade
C5
Dimensions (W*D*H) (mm)
800×1350×2380
Net Weight (T)
≤0.5
Communication
CAN/RS485/Ethernet
DCES 209kW-3C1
DC Side Parameters
Max DC Voltage (V)
1500
DC Voltage Range (V)
1000~1500
Max DC Current (A)
220*3
AC Side Parameters
Rated Power (kW)
209*3
Max Apparent Power (kW)
237*3
Rated Current (A)
174*3
Max Current (A)
198*3
Rated Voltage (Vac)
690 (3W+PE)
Grid Voltage (Vac)
586.5~759
Rated Frequency (Hz)
45~55/55~65
Basic Parameters
Overload Capability
1.1 times (long-term), 1.2 times (1min) (temp≤30°C)
Power Factor
~1~1 leading or lagging
Total Harmonic Distortion
<3% (rated load)
Operating Temperature (°C)
-35~60 (>45 derated)
Max Operating Altitude (m)
4000 (>2000 derated)
Relative Humidity
0~95%, no condensation
Protection Grade
IP45
Anticorrosion Grade
C5
Dimensions (W*D*H) (mm)
800×1350×2380
Net Weight (T)
≤0.6
Communication
CAN/RS485/Ethernet